What Is Cv? The Valve Flow Coefficient Explained

Every valve datasheet carries a Cv number, yet the definition is often half-remembered. This article pins down exactly what Cv measures, how it relates to Kv, and why one number can describe a valve across a huge range of services.

Globe valve internals showing plug and seat
Photo: Mairi Dulaney — Wikimedia Commons, CC BY-SA 4.0

1. The definition

Cv is the flow of water, in US gallons per minute, at 60 °F, that produces a pressure drop of 1 psi across a fully open valve. A valve with Cv = 100 passes 100 gpm of water with 1 psi of drop. Double the Cv and the same flow needs a quarter of the drop — because drop scales with the square of flow:

Q = Cv × √(ΔP / Sg)   ⇒   Cv = Q × √(Sg / ΔP)

Q in US gpm · ΔP in psi · Sg = specific gravity relative to water. For water, Sg = 1 and the square root terms collapse.

The square-root relationship is the whole story: flow is proportional to the square root of the driving drop. To pass twice the flow through the same valve you need four times the ΔP.

2. Kv — the metric twin

Metric practice uses Kv: the flow of water, in m³/h, that produces a pressure drop of 1 bar across a fully open valve (reference water temperature is defined in the range 5–30 °C depending on which standard edition applies). The two numbers are pure unit conversions of the same idea:

A "Cv 50" valve is a "Kv 43" valve. Datasheets listing both are the same capacity stated twice.

3. What Cv does not include

So Cv is the starting point of sizing, not the whole calculation. IEC 60534-2-1 is essentially a book of corrections around this one number.

4. A feel for the numbers

ServiceFlow (water)ΔPRequired Cv
Sample line5 gpm10 psi≈ 1.6
Small utility water50 gpm10 psi≈ 16
Process line500 gpm25 psi≈ 100
Header line2,000 gpm10 psi≈ 632

Typical catalogue: a 1 in globe trim spans Cv ≈ 5–20; a 6 in globe spans Cv ≈ 150–400; full-bore ball valves of the same 6 in can exceed Cv 900 — which is exactly why balls make poor throttling valves (huge capacity, almost no resolution near the seat).

5. The two questions Cv answers

  1. "Is the valve big enough?" — required Cv vs rated Cv at the maximum case, with choked-flow checked.
  2. "Where will it run?" — the ratio required-Cv/rated-Cv, mapped through the characteristic curve, tells you the operating travel. Keep it between ~20 % and ~80 % at normal load.
Try it: the Liquid Cv Calculator implements these equations with the choked-flow check built in. Definitions: flow coefficient (Cv/Kv). Next step: the full sizing procedure.
Editorial note. Definitions per ISA-75.01.01 and IEC 60534-2-1 conventions. Kv reference temperature varies slightly between standards (5–30 °C); the conversion factor 0.865 is unaffected at engineering accuracy. Engineering content is educational.